Pg 13 S22A/S23A 2001b 2100 v1.0
OPTION 4 :
With option 4 the vise open time can be adjusted. For changes of this setting contact
Hyd
.
Mech Saws as to the possible ramifications.
OPTION 3 :
With option 3 the setting value is the number of pulses sent by the blade speed proximity
sensor to the Sequencer for each revolution of the blade wheel. The setting for the S-23A is
320 pulses per revolution.
OPTION 2 :
With option 2 the Blade wheel circumference measured in feet, times a factor of ten
(Examples S-20A, 4.2 feet x 10 = 42, S-23A, 5.0 feet x 10 = 50), is entered into the
program. This value is used to calculate and display the blade speed.
OPTION 1 :
With option 1 the vice close delay interval (time from start of close to start of next operation)
can be adjusted. For changes of this setting contact Hyd
.
Mech Saws as to the possible
ramifications.
Parameter Options
1: Vise Close
Delay Time
2: Blade Wheel
Circumference
3: Blade Wheel
Pulses/Revolution
1: Vise Open
Time
0: Machine
Parameter Options Settings
The #INDEX display with the single digit is used to show which option is active and can be set.
The Options are:
OPTION 0 : With option 0 there are four machine characteristics settings. This function is the active
option default when the Parameter Setup is entered by holding down the #INDEX key as the PLC switch is
turned ON.
SETTING: 000
This is the default setting for normal S-20A machine operation of the vises, shuttle and
cutting head.
SETTING: 001
This setting changes the normal operation to allow the Shuttle Vise to remain closed and
for the Shuttle to remain in the forward position while the saw is cutting. This option is
useful to hold stock such as bundles until the cut is completed.
SETTING: 002
This setting changes the blade speed indicator to display the blade speed in Metric
measurement.
SETTING: 003
This setting combines 001 and 002 settings to allow both to be operational. With 003 the
blade speed will be displayed in Metric, the Shuttle will stay forward and the Shuttle vise
will remain closed until the cut is complete.