Pg 47 S22A / S23A mits 2001
Input / Output Terminal Information
Inputs -
X0 - Shuttle Encoder, Channel A X10 - Shuttle Vise Close Switch
X1 - Shuttle Encoder, Channel B X11 - Shuttle Vise Open Switch
X2 - Blade Speed X12 - Front Vise Close Switch
X3 - Blade Stop X13 - Front Vise Open Switch
X4 - Head Raise L/S X14 - Head Raise S/S
X5 - Head Lower L/S X15 - Head Lower S/S
X6 - Coolant Switch X16 - Blade Start
X7 - Coolant Switch X17 - Cycle Start
Outputs - Y0 - Machine Latch Y10 - Front Vise Close
Y1 - Open Y11 - Front Vise Open
Y2 - Open Y12 - Shuttle Fast
Y3 - Shuttle Vise Close Y13 - Open
Y4 - Blade Motor Contactor Y14 - Shuttle Rev
Y5 - Shuttle Vise Open Y15 - Shuttle Fwd
Y6 - Coolant Pump On/Off Y16 - Head Raise
Y7 - Cycle On Y17 - Head Lower
Y17 - Head Lower Relay
ENCODER and PROXIMITY SENSOR CONNECTIONS