Pg 25 S22A/S23A 2001b 2100 v1.0
HYDRAULIC FEED CONTROL
The Hydraulic Feed Control is located adjacent to the drive wheel box. These controls allow independent control
of Feed Force and Feed Rate.
Hydraulic Feed Control
Fast Approach Lever
Depress for fast head descent.
Feed Force Knob
Used to set Feed Force Limit (counter clockwise
rotation to increase and clockwise rotation to decrease).
Feed Rate Knob
Used to control speed of Head Descent. The scale
reads inches per minute.
CUTTING PARAMETERS CHART
A full size CUTTING PARAMETERS CHART is mounted on the drive door of the saw. The chart contains five
steps for the operator to follow in order to achieve optimum performance of the saw. Examples of the correct use of
this chart are on the following pages.
Saw Cutting Parameters Chart