Pg 4.4 V18
NOTE:
IF THE DRIVE MOTOR IS TO BE REPLACED, IT MUST BE REPLACED WITH A NON-VENTED
MOTOR TO PREVENT COOLANT LEAKING INTO THE MOTOR.
V18 II POWER COMPONENTS for SPECIFIC VOLTAGES
MACHINE VOLTAGE
3ph 208V 3ph 240V 3ph 380 3ph 415V 3ph 480V 3ph 600V
CONTACTOR (1M)
LC1D1210G6 LC1D1210G6 LC1D1210G6 LC1D1210G6 LC1D1210G6 LC1D1210G6
Telemecanique
AUX. CONTACT BLOCK (1M)
Telemecanique
THERMAL OVERLOAD
(1 O/L)
LR2D1312 LR2D1312 LR2D1308 LR2D1308 LR2D1308 LR2D1308
Telemecanique
MOTOR F.L.A.
(1750 RPM)
6.5 A 6.4 A 3.5 A 3.2A 3.2A 2.5A
FUSE SIZE &
11A
TEMPORARILY
UNAVAILABLE
Mitsubishi
FUSE SIZE &
30310
-Gould
TRANSFORMER PART #
(TR)
9070 T750D3 9070 T750D1 9070 T750D33 9070 T750D33 9070 T750D1 9070 T750D5 Square-D
PRIMARY FUSE SIZE &
30310
Gould
SECONDARY FUSE SIZE &
USM1
Gould
LINE REACTOR PART #
(480, 575 VAC ONLY)
- - - - MTE RL-01202 - MTE Corporation
DISCONNECT RATING (A) &
PART #
VCCF2
Telemecanique
CONTROL TRANSFORMER (TR) 750 VA
Description & (Item Code)
as on schematic
Component
Manufacturer
2
HP HYDRAULIC PUMP MOTOR (1M) Frame Size 145TC, 1800 R.P.M.
7.5HP BLADE DRIVE MOTOR (2M) Frame Size 184TC, 1800 R.P.M.