HPR130 Manual Gas Instruction Manual 5-53
6
Gas flows continued
P
NP
16. Perform gas leak test
A. Oxygen pressure drop at ____________
psi in 10 minutes ( ____________ bar)
B. Nitrogen pressure drop at ____________
psi in 10 minutes ( ____________ bar)
P
NP
17. Inspect for hose restrictions
P
NP
A. Motor valve hoses
P
NP
B. Gas console to motor valve
P
NP
C. Off-valve to torch body
P
NP
D. Hoses in power track
Cable connections
P
NP
18. Inspect cables
P
NP
A. CommandTHC
P
NP
B. Control cable from off-valve to
gas console
P
NP
C. From ignition console and gas
console to power supply
Ignition console
P
NP
19. Inspect for moisture, dust and
particulates
P
NP
20. Inspect spark gap subassembly
P
NP
21. Inspect torch leads
System grounding
P
NP
22. Inspect for proper system
component grounding
P
NP
23. Inspect connection from cutting
table to workpiece (+) lead
Power supply
P
NP
1. Inspect for particulates and blow out
P
NP
2. Inspect wiring harnesses
P
NP
3. Inspect main contactor
P
NP
4. Inspect pilot arc relay
Coolant system
P
NP
5. Inspect filter element
P
NP
6. Perform coolant flow tes t
A. Coolant flow checked at _________
gallons per minute ( _________ l/min)
Torch main body
P
NP
7. Inspect water tube
P
NP
8. Inspect current ring
P
NP
9. Clean threads on torch front end
P
NP
10. Inspect Vespel torch insulator
P
NP
11. Inspect torch and consumable o-rings
P
NP
12. Verify proper fit of retaining or shield cap
P
NP
13. Inspect hose fittings
P
NP
14. Inspect torch-to-torch-lead connections
Gas flows
P
NP
15. Inspect plumbing from gas supply
P
NP
A. Oxygen
P
NP
B. Nitrogen
P
NP
C. Air
P
NP
D. Nitrogen-Hydrogen
P
NP
E. Argon-Hydrogen
P
NP
F. Inspect compressed air filter system
Preventive Maintenance Protocol Checklist
Customer:
Location:
Contact:
Date:
Hypertherm system:
System serial #:
System arc hours:
(if equipped with an hour meter)
Comments P –
Performed
NP
Not present on system
Preventive maintenance performed by: Date: