SPECIFICATIONS
HPR130 Manual Gas Instruction Manual 2-5
6
Power supply
General
Maximum OCV (U
0
) 311 VDC
Maximum output current (I
2
) 130 Amps
Output voltage (U
2
) 50 – 150 VDC
Duty cycle rating (X) 100% @ 19.5 kw, 40° C (104° F)
Ambient temperature/Duty cycle Power supplies will operate between -10° C and +40° C (+14° and 104° F)
Power factor(cosϕ)
0.88 @ 130 ADC output
Cooling Forced air (Class F)
Insulation Class H
Part
number
AC Voltage
(U
1
)
Phase
Frequency
(Hz)
Amperage (I
1
)
Regulatory
approval
Power kW (+/- 10%)
(U
1
x I
1
x 1.73)
078177 200/208 3 50/60 62/60 CSA 21.5
078178 220 3 50/60 57 CSA 21.5
078179 240 3 60 52 CSA 21.5
078193 380 3 50/60 33 CCC 21.5
078180 400 3 50/60 32 CE/GOST-R 21.5
078182 440 3 50/60 28 CSA 21.5
078181 480 3 60 26 CSA 21.5
078183 600 3 60 21 CSA 21.5
317.5 kg
700 lb
154.9 mm
6.1"
1079.5 mm
42.5"
967.7 mm
38.1"
566.4 mm
22.3"

Table of Contents

Other manuals for Hypertherm HPR130

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HPR130 and is the answer not in the manual?

Hypertherm HPR130 Specifications

General IconGeneral
BrandHypertherm
ModelHPR130
CategoryWelding System
LanguageEnglish

Related product manuals