EasyManuals Logo

Hypertherm HPR130 User Manual

Hypertherm HPR130
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
INSTALLATION
HPR130 Manual Gas Instruction Manual 3-39
6
0
0
0
0
0
0
0
0
-7
-6
-5
-4
-3
-2
-1
10
20
30
40
0 102030405060
-57
-51
-46
-40
-34
-29
-23
-18
-12
-7
-1
4
Temperature
% of Propylene Glycol
Caution: For operating temperatures colder than the temperature stated above,
the percentage of propylene glycol must be increased. Failure to do so
could result in a cracked torch head, hoses or other damage to the torch
coolant system due to freezing.
Hypertherm pre-mix (028872)
Maximum glycol percentage
°F°C
Coolant for cold operating temperatures (below 0° C / 32° F)
Use a custom coolant mix when operating in temperatures below 0° C (32° F).
Use the chart below to determine what percentage of propylene glycol to use in the mixture.
Mix 100% glycol (028873) with the premixed Hypertherm coolant (028872) to increase the percentage of glycol. The
100% glycol solution can also be mixed with purified water (see next page for water purity requirements) to achieve the
required protection from freezing.
Note: Maximum percentage of glycol should never exceed 50%.

Table of Contents

Other manuals for Hypertherm HPR130

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HPR130 and is the answer not in the manual?

Hypertherm HPR130 Specifications

General IconGeneral
BrandHypertherm
ModelHPR130
CategoryWelding System
LanguageEnglish

Related product manuals