INSTALLATION
HPR130 Manual Gas Instruction Manual 3-31
6
Torch connections
Connect the torch to the torch lead assembly
1. Uncoil the first 2 meters (6.5 feet) of the leads on a flat surface.
2. Hold the torch assembly in place with the spanner wrench (104269) and remove the mounting sleeve from the torch
assembly.
3. Push back the braided cover and slide the sleeve over the leads. Align the torch with the hoses in the lead assembly.
The hoses must not be twisted. They are taped together to help prevent twisting.
4. Connect the coolant IN hose (green) to the torch.
Braided cover
Sleeve
Coolant IN hose
2WRENCHES