INSTALLATION
3-46 HPR400XD Manual Gas Instruction Manual
0
0
0
0
0
0
0
0
-7
-6
-5
-4
-3
-2
-1
10
20
30
40
0 102030405060
-57
-51
-46
-40
-34
-29
-23
-18
-12
-7
-1
4
Temperature
% of Propylene Glycol
Caution: For operating temperatures colder than the temperature stated above,
the percentage of propylene glycol must be increased. Failure to do so
could result in a cracked torch head, hoses or other damage to the torch
coolant system due to freezing.
Hypertherm pre-mix (028872)
Maximum glycol percentage
°F°C
Custom Coolant mix for cold operating temperatures (below -12° C / 10° F)
Use the chart below to determine what percentage of propylene glycol to use in the mixture.
Mix 100% glycol (028873) with the premixed Hypertherm coolant (028872) to increase the percentage of glycol. The
100% glycol solution can also be mixed with purified water (see next page for water purity requirements) to achieve the
required protection from freezing.
Note: Maximum percentage of glycol should never exceed 50%.
Freezing Point of Propylene Glycol Solution
10/16/08