INSTALLATION
3-34 HPR400XD Manual Gas Instruction Manual
1. Locate terminal block 2 (TB2) in the power supply.
2. Remove wire 1 as shown and connect it to terminal 2.
3. Connect switch to terminals 1 and 2 as shown.
Note: The main power switch on the gas console must be in the ON position for the remote switch to
function.
123
1
3
TB2
13
123
1
3
TB2
13
Note: Use a switch, relay or solid-state relay that is
compatible with 24 VAC @ 100 mA. It must
be a maintained-contact switch, not a
momentary-contact switch.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
See the Safety section in this manual for more safety precautions.
Remote ON/OFF switch (provided by customer)
TB2 location