OPERATION
4-46 HPR400XD Manual Gas Instruction Manual
Stainless steel
H35 Plasma / N
2
Shield
400 A
Flow rates – lpm/scfh
H35 N
2
Preflow 0 / 0 189 / 400
Cutflow 86 / 182 123 / 260
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts mm mm/m mm Factor % Seconds
H35
N
2
35 80 86 80
20
180
9.0
1100 14.5 150 0.7
25
181 905
19.0 210
1.0
30
184 800 1.5
40
186 600 2.0
50
192 400
Edge start
60
198 280
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts in ipm in Factor % Seconds
H35
N
2
35 80 86 80
3/4
180
0.35
45 0.53 150 0.7
1
181 35
0.75 210
1.0
1-1/4
184 30 1.5
1-1/2
186 25 2.0
1-3/4
189 20
Edge start
2
192 15
2-1/4
198 12
2-1/2
202 10
English
220707220637 220709220712 220405220708
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm in mm/min ipm Volts
N
2
N
2
10 10 10 10
22
2.5 0.10 1270 50 94
ArAir30103010
24
3.0 0.12 2540 100 50
220571