EasyManua.ls Logo

Hypertherm HyPerformance HPR400XD - Page 231

Hypertherm HyPerformance HPR400XD
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
HPR400XD Manual Gas Instruction Manual 5-61
Preventive Maintenance Master Schedule
Daily:
Verify proper inlet gas pressure.
Verify proper gas flow settings. – Mandatory at every consumable change.
Inspect torch and replace consumables as needed.
Weekly:
Week Jan Feb March April May June July Aug Sept Oct Nov Dec
1
2
3
4
5
Semi-Annually:
Year 1
st
Service 2
nd
Service
Clean power supply with dry, oil free compressed air, or a vacuum cleaner.
Verify cooling fans are working properly.
Clean torch threads and current ring.
Verify proper coolant level.
Annually:
Year
Replace service parts per the Service Part Replacement Schedule.
Replace service parts per the Service Part Replacement Schedule.

Table of Contents

Related product manuals