4321
1
A
432
A
B
C
D
B
C
D
Interface
CNC
(Customer Supplied)
141030
CONTROL BOARD
S301
12
J300
343214
J303A J303B
CNC Interface Cable
Workpiece
CNC Interface Cable
(Optional Unit)
THC
Command
CNC Interface Cable
Pendant Ext. Cable
(Optional Unit)
Operator
Pendant
Lifter
Torch
(Optional Unit)
Motor Drive Cable
Lifter I/O Interface Cable
J2B
J2A
PLASMA INTERFACE BD
041842
Serial ID
Dipswitch
Jumper Block
Machine Motion
CNC Interface Cable
Command I/O Cable-Second THC
Command I/O Cable-Third THC
Command I/O Cable-Fourth THC
12
J104
12
J105
Optional Command THC Interface
13245678
Dipswitch
Serial ID
S301
12345 768
S301
Dipswitch
Serial ID
12345 768
S301
Dipswitch
Serial ID
1234 6587
To rch
HPR PAC
Dry Cutting System
Notes:
1) For a single system installation set Serial ID (S301),
Machine Motion (J300), J104 & J105 as shown
2) For a two system installation duplicate a second power supply and Command THC
as illustrated for a single system, set Serial ID as shown for the second system
3) For a three system installation set up as described above, set Serial ID as shown
for the third system
4) For a four system installation set up as described above, set Serial ID as shown
for the fourth system
5) All machine interface cables (Pwr. supply-CNC) used for serial communication between
Pwr. supply-CNC will have a common connection node with the CNC
6) The CNC will need a dedicated I/O port for each Command THC
7) If a Hypertherm Automation controler is being used, and there are intermittent communication failures
(PS Link Failure), try removing the jumpers on J104 and J105 on the control board, and the
termination jumper (J6 or J8) on the serial isolation board in the controler. Only remove the
termination jumper on the serial isolation board that is connected to the HPR power supply.
See sheet 19 of 20 for more details.
See Command THC Manual for
internal Power Supply wiring
ELEC SCH:HPR400 PWR SPLY
B
013373
SHEET 19 OF 19
7-25
Dipswitch setting example:
Switch 1 is in the ON position.
Switches 2-8 are in the OFF position.