Operation
TOTALS (DI1)
Y’day 55.6
Day 17.8
Run 5432.4
TOTALS (DI2)
Y’day 134.7
Day 26.4
Run 11276.3
4.3.4.8 Reset Totals Screen
Note: This screen is only available if there is an authorised user logged in.
The Total Reset screen is used to reset the daily and running totals for both inputs. Press the Alt key for at least 3 seconds
reset the daily and running totals for both DI1 and DI2.
RESET TOTALS
Press Alt key for 3
seconds to reset all
totals.
A message indicating that the reset has occurred will then be displayed. Pressing the + key will resume the LCD screen
sequence.
RESET TOTALS
All totalisers have
been reset to zero!
4.3.4.9 Call-Back Test Screen
Note: This screen is only available if there is an authorised user logged in and the unit is configured for Telemetry mode.
The Call-back Test screen can be used to initiate a call-back to the designated telemetry base station (usually HydroTel).
Pressing the Alt key will initiate the test call. The envelope icon will appear while the call-back test is waiting for an
acknowledgement from the base station.
If a successful acknowledgement is received, the icon will disappear. If the call is not acknowledged, the iRIS will repeat the
call back every minute. The number of call attempts is displayed on the bottom line of the display. There is a maximum of
ten call attempts possible.
CALL-BACK TEST
Press Alt key to
initiate test call.
Attempts: 0