www.hysecurity.com Display Menu D0536 Rev. C 3-5
User Menu Setting Options Menu Tasks & Explanations SDC Wire
Connections
BF 0 (OFF)
Warn Before Operate
0 = off
1 = warning buzzer on
throughout Gate travel
2=warningbuzzeronfor2
secondsofGatetravel
Controlsthewarn-before-operatebuzzerandcanbe
conguredthreeways:
Setto0:Buzzerisdisabled.Thebuzzerwillstillbeep
if alerts, faults, errors, or entrapment occur.
Setto1:Buzzerbeepsfor3secondsbeforegate
moves and continues through entire length of travel.
Setto2:Buzzerbeepsfor3sbeforegatemovesand
continues for 2s of travel.
Notapplicable(N/A)
FA0(OFF)
ForcedOpenAlert
0 = off
1=on
Intended for highly secure facilities.
Setto1,theoperatorsoundsthe3-second“warn
beforeoperate”buzzeralarmandinitiatesaclosure
if the gate is forced open and the closed limit switch
disengages. The motor starts to secure the gate. If
the gate does not fully close within 4s, the motor
turnsoffandthebuzzersoundsfor30seconds.The
displayshowsALERT1-FORCEDOPEN.
N/A
DA0(OFF)
DriftCloseAlert
0 = off (standard)
1=on(detailed)
Setto1,theoperatorsoundsthe3-second“warn
beforeoperate”buzzeralarmandinitiatesanopen
command if the gate is forced, or drifts, off the open
limit switch. The motor starts to reopen the gate. The
motor runs for a maximum of 4s and, if the gate is
notfullyopenattheendofthisperiod,thebuzzer
soundsfor10s.ThedisplayshowsALERT2-DRIFT
CLOSED.
N/A
PE0(OFF)
PhotoEyeAlignment
0 = off
1=on
Setto1,theoperatorservesasanaideinphoto
eyetransmitter/receiveralignment.Thebuzzer
chirps once when the emitter and receiver are not
aligned. When the emitter and receiver are aligned,
thebuzzerchirpstwice.Iftheygooutofalignment
again,thebuzzerwillchirponce.TheAlignment
Mode is reset with a close-limit input or by pressing
the Reset button.
NOTE: If the operator doesn’t run when the power
switch is initially turned ON, check the alignment of
the photo eye and all the photo eye connections.
EYEOpen
EYEClose
EYECOM
CL 0
Set Clock
0 = Display
1=SetClock
To adjust the hour, minute, day, or month to a
differenttimezone,select1.Oncetheclockisset,
the display returns to the 0 setting.
This feature is useful to read historic operational
data, which can be accessed with a computer via the
USB or RS-232 port.
N/A
LD 5
LCD Contrast
5
0through9
Adjuststhecontrastofthedisplay.Availablesettings
fromlowcontrast0to9highcontrast,withafactory
default setting of 5.
NOTE: While the Operator Status Displays are scroll-
ing, you also have the ability to adjust the contrast by
pressingthePREVandNEXTbuttons.
N/A
US 0
CLEARCOUNT
0 = preprogrammed limit
1=ClearTransientcount
2=ClearTenantcount
3=ClearSpecialcount
4=AllUser
Clearsthelogs(counts)of“usertypes”enteringor
exitingthroughtheStrongArmParkDCgate.This
menu is used most often in Parking lot and revenue
control scenarios. Selecting a number and pressing
SELECTagain,clearsthecount.
COM
TRANSIENTUSER
TENANTUSER
SPECIALUSER

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HySecurity StrongArmPark DCS 14 and is the answer not in the manual?

HySecurity StrongArmPark DCS 14 Specifications

General IconGeneral
BrandHySecurity
ModelStrongArmPark DCS 14
CategoryGate Opener
LanguageEnglish

Related product manuals