3-14 D0536 Rev. C StrongArmPark DC: Programming & Operations Manual www.hysecurity.com
settIng tHe Close tImer
Asanaddedsecuritymeasureandtomakesurethebarrierarm
closes automatically within a reasonable time frame after all loops
are cleared, you must set the Close Timer.
The Close Timer assigns how many seconds will pass before the
operator initiates closure of a fully opened barrier arm after all
open commands and reversing sensor inputs have ceased and
loopscleared.Everygateoperatorneedstohavetheclosetimer
settoaspecicnumberofseconds(forexample,5seconds)
unless a hard-wired closing device is connected to the unit, such
asa“holdtoclose”pushbuttonstation.
Toadjustthetime(1to99seconds)ittakesbeforetheoperatorinitiatesgateclosure,takethefollowingsteps:
1. Atagatestatusdisplay,presstheMENUbuttontwice.ThisaccessestheUserMenuandtheCloseTimer
display appears.
NOTE: If you want gate personnel to operate the gate with the Hold to Close feature found in some push button
stations, then set the Hold to Close menu item to 1. When the Hold to Close menu item is active (set to 1), the
Close Timer menu item is unavailable.
2. Use the Select, and then Next or Previous buttons to change
the number of seconds appearing on the display.
3. ToexittheUserMenu,presstheMENUbutton.Thegate
status appears in the display indicating you have returned to
Run Mode.
CT 15 (SECS)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
Status Display
GATE CLOSED
User Menu
CT 0 (OFF)
CT 1 (ON)
CLOSE TIMER
CT 10 (SECS)
CLOSE TIMER