3-6 D0536 Rev. C StrongArmPark DC: Programming & Operations Manual www.hysecurity.com
User Menu Setting Options Menu Tasks & Explanations SDC Wire
Connections
DS 0 (OFF)
Diagnostic Logs
0 = off
1=detailed
Set to 0, the SDC logs pertinent operator events
such as faults, errors, or menu manipulation. When
experiencing intermittent problems, set this item to
1torecordalloperatoropenandcloseevents,in
addition to the normal alert, fault and error logs. This
parameter automatically resets to the default 0 (off)
after 24 hours.
USB or RS-232 cable
and laptop computer
loaded with HySecurity
freeS.T.A.R.T.softwareis
required to read the log
le.
Visitwww.hysecurity.com
PD 0
Set Password
0 = Off
1=On,SetPassword
To enter a password (up to 80 characters) for
networkconnectivity,select1.Youcanusethemenu
navigationbuttonstoenterthepassword(SELECT,
NEXT,SELECT).Whenthepasswordisset,the
display returns to the 0 setting.
NOTE:ASystemAddress(SA)valueintheInstaller
Menu must be set before the Set Password display
can appear in the User Menu.
Network:Ethernetor
RS-485
Installer menu
TheInstallerMenuoptionsprovidemoreadvancedcongurationsfor
thegateoperators.AccesstotheInstallerMenuisthroughtheUser
Menu. The navigational buttons are the same in both menu modes.
Access:
WhileastaticRunModecodeisbeingdisplayed,presstheMENU
button twice. (Bypasses the operator status displays.)
When the Close Timer display appears:
1. AccesstheInstallerMenubysimultaneouslypressingandhold-
ingtheRESETandOPENbuttons.
2. Release both buttons and the Learn Limit display appears. The
LLdisplayistherstitemintheInstallerMenu.
NOTE: Installer Menu options can also be congured through the use of a lap-
top computer and the S.T.A.R.T. software.
Table 2 describes the Installer Menu items and supplies the factory defaults. (Factory settings shown in bold.)
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT