3-12 D0536 Rev. C StrongArmPark DC: Programming & Operations Manual www.hysecurity.com
AccesstotheInstallerMenuisthroughtheUserMenu.Seetheowchartbelow.
Learn Open Limits
1. PressandholdtheOPENbuttonwhilethedegreesincreasetoward
90andthebarrierarmreachesthedesiredfullopenposition.
2. ReleasetheOPENbuttonasthearmnearsfullopen.Themotorslowsasdothenumberedincrementson
thedisplay.Notethatifyougotoofar,youcanpressCLOSEtoreversedirection.
3. PressSTOPtwicetopreservetheopenstoplocation.Thebuzzerchirpstwiceandthefullopenstopis
retained in memory.
Learn Close Limits
1. PressandholdtheCLOSEbuttonwhilethedegreesincreasetoward-90andthebarrierarmreachesthe
desired full open position.
2. ReleasetheCLOSEbuttonasthearmnearsfullopen.Themotorslowsasdothenumberedincrements
onthedisplay.Notethatifyougotoofar,youcanpressOPENtoreversedirection.
3. PressSTOPtwicetopreservetheopenstoplocation.Thebuzzerchirpstwiceandthefullopenstopis
retained in memory.
test tHe operator
Complete the installation by testing the operation of the gate.
LEARN OPEN
DEGS: +XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LEARN CLOSE
DEGS: - XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
Status Display
GATE CLOSED
User Menu
CT 0 (OFF)
Installer Menu
LL 0 (OFF)
Learn Limits
LL 1 (ON)
LEARN OPEN
DEGS: +XXX.X
PressMENUtwiceat
the Run Mode static
display.
To access the Installer Menu,
pressandholdRESET&
OPEN,andthenreleasethem.
Press Select.
The“LL”charactersblink.
To activate the learn limits
function, press Next which
changesthedisplaytoLL1.
Press Select. The
LearnOPENblinksin
the display indicating
that the operator is
ready to relearn the
closed limit.