3-12 D0536 Rev. C StrongArmPark DC: Programming & Operations Manual www.hysecurity.com
AccesstotheInstallerMenuisthroughtheUserMenu.Seetheowchartbelow.
Learn Open Limits
1. PressandholdtheOPENbuttonwhilethedegreesincreasetoward
90andthebarrierarmreachesthedesiredfullopenposition.
2. ReleasetheOPENbuttonasthearmnearsfullopen.Themotorslowsasdothenumberedincrementson
thedisplay.Notethatifyougotoofar,youcanpressCLOSEtoreversedirection.
3. PressSTOPtwicetopreservetheopenstoplocation.Thebuzzerchirpstwiceandthefullopenstopis
retained in memory.
Learn Close Limits
1. PressandholdtheCLOSEbuttonwhilethedegreesincreasetoward-90andthebarrierarmreachesthe
desired full open position.
2. ReleasetheCLOSEbuttonasthearmnearsfullopen.Themotorslowsasdothenumberedincrements
onthedisplay.Notethatifyougotoofar,youcanpressOPENtoreversedirection.
3. PressSTOPtwicetopreservetheopenstoplocation.Thebuzzerchirpstwiceandthefullopenstopis
retained in memory.
test tHe operator
Complete the installation by testing the operation of the gate.
LEARN OPEN
DEGS: +XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LEARN CLOSE
DEGS: - XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
Status Display
GATE CLOSED
User Menu
CT 0 (OFF)
Installer Menu
LL 0 (OFF)
Learn Limits
LL 1 (ON)
LEARN OPEN
DEGS: +XXX.X
PressMENUtwiceat
the Run Mode static
display.
To access the Installer Menu,
pressandholdRESET&
OPEN,andthenreleasethem.
Press Select.
The“LL”charactersblink.
To activate the learn limits
function, press Next which
changesthedisplaytoLL1.
Press Select. The
LearnOPENblinksin
the display indicating
that the operator is
ready to relearn the
closed limit.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HySecurity StrongArmPark DCS 14 and is the answer not in the manual?

HySecurity StrongArmPark DCS 14 Specifications

General IconGeneral
BrandHySecurity
ModelStrongArmPark DCS 14
CategoryGate Opener
LanguageEnglish

Related product manuals