6. Operating and Storage Environment
6.1 Operating Environment
The actuator should be set up in an environment, which meets the following criteria:
Avoid direct sunlight.
Avoid radiant heat from strong heat sources such as a furnace.
Ambient temperature should be 0 - 40°C.
The humidity should be less than 85% and there should be no condensation.
Avoid exposure to corrosive or combustible gases.
The area should have very little dust and be suitable for normal assembly operation.
Avoid exposure to oil mist or fluids used in cutting.
The unit should not be subject to impact or vibrations.
Avoid extreme electromagnetic waves, ultraviolet rays and radiation.
This product is not intended to be used in a chemical environment.
In general, the environment should be one in which an operator can work without protective equipment or
protective clothing.
Work space needed for maintenance/inspection
6.2 Storage Environment
The storage environment should be similar to the operating environment. In addition, you must take
precautions against condensation if the unit is to be stored for a long period of time. Unless there are special
instructions, we do not include moisture absorption agents when shipping the unit. If you are storing the unit
where condensation might occur, then you must treat the entire package from outside of the package or treat
the unit itself after it is unpacked to prevent condensation. The unit can withstand up to 60°C during a short
storage interval but only up to 50°C if the storage period is longer than one month.