The body of the base warps easily when the actuator is used as the Y-axis in an X-Y overhang setup. In this
case, use the actuator so that the Ma and Mc moments are kept to one-half the allowable moment or less (see
the figure below).
Caution: Allowing the slider to receive an excessive load moment will shorten the service life of the guides. If
the allowable overhang length is exceeded, vibration may generate or the service life of the guides
may be reduced.
Y-axis
X-axis
The Ma and Mc moments applied
on this slider should be kept to
one-half the allowable moment.