B15611B1
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B15611B9
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B15611BA
Explanation: The service processor could not communicate with the Chassis Management Module.
Response: Go to Reseating the compute node in a chassis.
B1768BBF
Explanation: During the configuration of the second interface connection, the service processor detected that the
interface is not connected to an active CMM.
Response: If a service processor reset to factory default was performed or if this is a tracking event, no service
actions are required. Otherwise, use the FRU and procedure callouts detailed with the SRC to determine service
actions.
B1817200
Explanation: Invalid boot request
Response: Go to Checkout procedure.
B1817201
Explanation: Service processor failure
Response: Go to Checkout procedure.
B1817202
Explanation: The permanent and temporary firmware sides are both marked invalid
Response: Go to Checkout procedure.
B1817203
Explanation: Error setting boot parameters
Response: Go to Checkout procedure.
B15611B1 • B1817203
144 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals