EasyManua.ls Logo

IBM Flex System p260 - Ffc_B88

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26B4-118
Explanation: A SCSI command time-out occurred. Replace each part reported by the diagnostic program one at a
time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
v FFC_B88
26B4-120
Explanation: A SCSI busy or command error. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-122
Explanation: A SCSI reservation conflict error. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-124
Explanation: A SCSI check condition error occurred. Replace each part reported by the diagnostic program one at a
time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-118 26B4-124
358 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Related product manuals