Explanation: A SCSI command time-out occurred. Replace each part reported by the diagnostic program one at a
time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
v FFC_B88
26B4-120
Explanation: A SCSI busy or command error. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-122
Explanation: A SCSI reservation conflict error. Replace each part reported by the diagnostic program one at a time.
Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-124
Explanation: A SCSI check condition error occurred. Replace each part reported by the diagnostic program one at a
time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
26B4-118 • 26B4-124
358 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide