EasyManua.ls Logo

IBM Flex System p260 - Page 371

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26B4-126
Explanation: A software error was caused by a hardware failure. Replace each part reported by the diagnostic
program one at a time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next
part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
v FFC_B88
26B4-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26BD
v FFC_B88
v FFC_26B4
26B4-129
Explanation: Error log analysis indicates a SCSI bus problem. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26BD
v FFC_B88
v FFC_26B4
26B4-130
Explanation: Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Replace
the 200 GB SATA Solid State Drive.
Response:
Failing Item:
v FFC_26B4
26B4-126 26B4-130
Chapter 8. Troubleshooting 359

Table of Contents

Related product manuals