26B4-126
Explanation: A software error was caused by a hardware failure. Replace each part reported by the diagnostic
program one at a time. Retry the diagnostic test after each part is replaced. If the problem persists, replace the next
part in the list.
Response:
Failing Item:
v FFC_26B4
v FFC_26BD
v FFC_B88
26B4-128
Explanation: The error log analysis indicates a hardware failure. Replace each part reported by the diagnostic
program one at a time. Run the diagnostic program in problem determination mode on each part reported in the
original SRN. If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26BD
v FFC_B88
v FFC_26B4
26B4-129
Explanation: Error log analysis indicates a SCSI bus problem. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_26BD
v FFC_B88
v FFC_26B4
26B4-130
Explanation: Error log analysis indicates a problem reported by the disk drive's self-monitoring function. Replace
the 200 GB SATA Solid State Drive.
Response:
Failing Item:
v FFC_26B4
26B4-126 • 26B4-130
Chapter 8. Troubleshooting 359