B700F108
Explanation: A firmware error caused the system to terminate.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.
B700F10A
Explanation: System firmware detected an error
Response: Look for and correct B1xxxxxx errors.
B700F10B
Explanation: A processor resource has been disabled due to hardware problems
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B700F10C
Explanation: The platform LIC detected an internal problem performing Partition Mobility.
Response:
1. Collect the event log information.
2. Go to Isolating firmware problems.
B700F120
Explanation: Informational system log entry only.
Response: No corrective action is required.
B700F130
Explanation: Thermal Power Management Device firmware error was detected.
Response: Check for server firmware updates; then, install the updates if available.
BAxxyyyy partition firmware SRCs:
The power-on self-test (POST) might display an error code that the partition firmware detects. Try to
correct the problem with the suggested action.
B700F108 • B700F130
Chapter 8. Troubleshooting 189

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals