The BAxxyyyy SRCs below are the error codes that might be displayed if POST detects a problem. Follow
the suggested actions in the order in which they are listed until the problem is solved. If an action solves
the problem, then you can stop performing the remaining actions. See Chapter 7, “Parts listing for IBM
Flex System p260 and p460 Compute Nodes,” on page 97 to determine which components are CRUs and
which components are FRUs.
Note: For problems persisting after completing the suggested actions, see “Checkout procedure” on page
451 and “Solving undetermined problems” on page 498.
BA000010
Explanation: The device data structure is corrupted
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA000020
Explanation: Incompatible firmware levels were found
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA000030
Explanation: An lpevent communication failure occurred
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA000031
Explanation: An lpevent communication failure occurred
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA000010 BA000031
190 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide