B1818BC2
Explanation: The service processor was reset due to a communication failure with the Chassis Management Module.
Response: If this is tracking event, no service action is required. Otherwise look for Chassis Management Module
problems and resolve them.
B181D548
Explanation: An informational event was generated on the service processor.
Response: This is an informational tracking event and no service action is required.
B2xxyyyy logical partition SRCs:
A B2xxyyyy SRC is a logical partition reference code that is related to logical partitioning.
The B2xxyyyy SRCs below are the system reference codes that might be displayed if system firmware
detects a problem. Follow the suggested actions in the order in which they are listed until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions. See
Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
Note: For problems persisting after completing the suggested actions, see “Checkout procedure” on page
451 and “Solving undetermined problems” on page 498.
B2001020
Explanation: Firmware for the specified function cannot be loaded
The firmware resource and all associated virtual and/or physical devices will not be available until the issue is
resolved.
Response: Collect a platform dump and then go to Isolating firmware problems.
B2001130
Explanation: A problem occurred during the migration of a partition
You attempted to migrate a partition to a system that has a power or thermal problem. The migration will not
continue.
Response: Look for and fix power or thermal problems and then retry the migration.
B2001131
Explanation: A problem occurred during the migration of a partition.
The migration of a partition did not complete.
Response: Check for server firmware updates; then, install the updates if available.
B1818BC2 B2001131
146 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals