B7005603
Explanation: Enclosure feature code and/or serial number not valid.
Response: Verify that the machine type, model, and serial number are correct for this server.
B7006900
Explanation: PCI host bridge failure
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006906
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006907
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
B7006908
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006909
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
B7005603 B7006909
Chapter 8. Troubleshooting 179