B7005603
Explanation: Enclosure feature code and/or serial number not valid.
Response: Verify that the machine type, model, and serial number are correct for this server.
B7006900
Explanation: PCI host bridge failure
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006906
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006907
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
B7006908
Explanation: System bus error
Response: Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
assembly.
B7006909
Explanation: System bus error
Response:
1. Replace the system-board, as described in Replacing the system-board and chassis assembly.
2. Go to Isolating firmware problems.
B7005603 • B7006909
Chapter 8. Troubleshooting 179

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals