EasyManua.ls Logo

IBM Flex System p260 - Page 198

IBM Flex System p260
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B7006A22
Explanation: PCI-E switch had a recoverable failure, however, all downstream I/O had to be failed during recovery.
Recovery for the PCI-E switch failure is being attempted. If the recovery is successful, no other SRC is logged.
Response: Once the PCI-E switch is recovered, the downstream I/O adapters should recover. The partition or
application associated with the failed downstream I/O may have to be restarted.
B7006A23
Explanation: PCI-E switch recovery failure. All downstream I/O is failed.
Response: If there are any AIX or Linux errors logged against I/O adapters on this switch, do not replace any I/O
adapter hardware. This PCI-E switch failure is the root cause.
1. Collect error logs and info logs.
2. Collect the configuration data for the IOAs downstream of the PCI-E switch.
3. Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis assembly.
4. Although the partition or application may have continued to run after the I/O adapter failures, it might need to
be restarted to recover.
B7006A24
Explanation: PCI-E switch had an unrecoverable failure. All downstream I/O is failed.
Response:
1. Collect error logs and info logs.
2. Collect the configuration data for the IOAs downstream of the PCI-E switch.
3. Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis assembly.
Send the failed FRU and the data to IBM for fault analysis.
B7006A25
Explanation: PCI-E switch has detected a firmware action that was not valid. All downstream I/O is failed.
Response:
1. Collect error logs and info logs.
2. Collect the configuration data for the IOAs downstream of the PCI-E switch.
3. Update the firmware to the current level, as described in Updating the firmware.
4. If the problem persists, replace the system-board and chassis assembly, as described in Replacing the
system-board and chassis assembly. Send the failed FRU and the data to IBM for fault analysis.
B7006A22 B7006A25
186 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Related product manuals