CA00E15B
Explanation: Transfer control to operating system (service mode boot)
Response: Go to Boot problem resolution.
CA00E15F
Explanation: Adapter VPD evaluation
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E170
Explanation: Start of PCI bus probe
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E172
Explanation: First pass of PCI device probe
Response:
1. Go to Checkout procedure.
2. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E174
Explanation: Establishing host connection
Response:
1. Verify that:
v The bootp server is correctly configured; then, retry the operation.
v The network connections are correct; then, retry the operation.
2. If the problem persists:
a. Go to Checkout procedure.
b. Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA00E15B • CA00E174
Chapter 8. Troubleshooting 273