256D-701
Explanation: Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_256D
v FFC_221
256D-702
Explanation: Error Log Analysis indicates permanent adapter failure is reported on the other port of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_256D
v FFC_221
25C4-201
Explanation: Configuration error. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_25C4
25C4-601
Explanation: Download firmware error. Go to Performing the checkout procedure.
Response:
Failing Item:
v FFC_25C4
256D-701 • 25C4-601
334 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide