2604-105
Explanation: Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel Adapter
card.
Response:
Failing Item:
v FFC_2604
2604-106
Explanation: Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card. Replace the 4Gb
Fibre Channel Adapter card.
Response:
Failing Item:
v FFC_2604
2604-108
Explanation: Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go to Performing the
checkout procedure.
Response:
Failing Item:
v FFC_2604
v FFC_221
2604-110
Explanation: Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the 4Gb Fibre Channel
Adapter card.
Response:
Failing Item:
v FFC_2604
2604-201
Explanation: Configuration Register Test Failure for the Fibre Channel adapter card. Go to Performing the checkout
procedure.
Response:
Failing Item:
v FFC_2604
v FFC_221
2604-105 • 2604-201
336 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide