26D7-140
Explanation: Error log analysis indicates poor signal quality. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D7
26D7-640
Explanation: Error log analysis indicates a path error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
2710-101
Explanation: Error Log Analysis indicates adapter function failure. Replace the Integrated USB Controller.
Response:
Failing Item:
v FFC_2710
2710-601
Explanation: Error Log Analysis indicates adapter function failure. Replace the Integrated USB Controller.
Response:
Failing Item:
v FFC_2710
2750-201
Explanation: Adapter configuration error Replace the PCIe2 16Gb 2-port FC Mezzanine Adapter If the problem
persists, replace the system board.
Response:
Failing Item:
v FFC_2750
v FFC_221
26D7-140 2750-201
372 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide