EasyManuals Logo

IBM Flex System p260 User Manual

IBM Flex System p260
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #384 background imageLoading...
Page #384 background image
26D7-140
Explanation: Error log analysis indicates poor signal quality. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v FFC_B88
v FFC_26D7
26D7-640
Explanation: Error log analysis indicates a path error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v FFC_26D7
2710-101
Explanation: Error Log Analysis indicates adapter function failure. Replace the Integrated USB Controller.
Response:
Failing Item:
v FFC_2710
2710-601
Explanation: Error Log Analysis indicates adapter function failure. Replace the Integrated USB Controller.
Response:
Failing Item:
v FFC_2710
2750-201
Explanation: Adapter configuration error Replace the PCIe2 16Gb 2-port FC Mezzanine Adapter If the problem
persists, replace the system board.
Response:
Failing Item:
v FFC_2750
v FFC_221
26D7-140 • 2750-201
372 Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System p260 and is the answer not in the manual?

IBM Flex System p260 Specifications

General IconGeneral
BrandIBM
ModelFlex System p260
CategoryServer
LanguageEnglish

Related product manuals