2D29-720
Explanation: Controller devce bus configuration error. Use MAP3150 to determine resolution.
Response:
2E00-201
Explanation: Configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E00
v FFC_221
2E00-601
Explanation: EEPROM read error
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E00
2E00-701
Explanation: Permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E00
v FFC_221
2D29-720 • 2E00-701
Chapter 8. Troubleshooting 379