2E15-702
Explanation: Error Log Analysis indicates permanent adapter failure is reported.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E15
v FFC_221
2E16-201
Explanation: Adapter configuration error. Replace the IBM Flex System FC3172 2-port 8Gb FC Adapter. If the
problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E16
v FFC_221
2E16-601
Explanation: Error log analysis indicates adapter failure. Replace the IBM Flex System FC3172 2-port 8Gb FC
Adapter.
Response:
Failing Item:
v FFC_2E16
2E16-602
Explanation: Error log analysis indicates an error attention condition. Replace the IBM Flex System FC3172 2-port
8Gb FC Adapter.
Response:
Failing Item:
v FFC_2E16
2E15-702 2E16-602
Chapter 8. Troubleshooting 389