2E21-701
Explanation: Error Log Analysis indicates permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E21
v FFC_221
2E21-702
Explanation: Error Log Analysis indicates permanent adapter failure is reported on the other port of this adapter.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E21
v FFC_221
2E23-101
Explanation: Register Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E23
2E23-102
Explanation: VPD Checksum Test Failure
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E23
2E21-701 2E23-102
Chapter 8. Troubleshooting 393