2E36-701
Explanation: Permanent adapter failure.
1. Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Response:
Failing Item:
v FFC_2E36
v FFC_221
2E37-111
Explanation: Enhanced Error Handling failure on bus. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet
Adapter.
Response:
Failing Item:
v FFC_2E37
2E37-112
Explanation: Enhanced Error Handling failure while testing adapter. Replace the IBM Flex System EN4054 4-port
10Gb Ethernet Adapter. If the problem persists, replace the system board.
Response:
Failing Item:
v FFC_2E37
v FFC_221
2E37-140
Explanation: DMA read test failed. Replace the IBM Flex System EN4054 4-port 10Gb Ethernet Adapter.
Response:
Failing Item:
v FFC_2E37
2E36-701 2E37-140
Chapter 8. Troubleshooting 403