2D14-FF3D
Explanation: Temporary controller failure. Retry the operation. Replace the system board (SAS controller).
Response:
Failing Item:
v FFC_2D14
2D14-FFF3
Explanation: Disk media format bad. Reformat the disk and retry the operation. Use MAP3135 to determine
resolution.
Response:
2D14-FFF4
Explanation: Device problem. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-FFF6
Explanation: Device detected recoverable error. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-FFFA
Explanation: Temporary device bus error. Replace the FRU identified by diagnostics.
Response:
Failing Item:
v FFC_722
2D14-FFFE
Explanation: Temporary device bus error. Use MAP3150 to determine resolution.
Response:
2D14-FF3D • 2D14-FFFE