Table 16. Failing function codes (continued)
FFC Description and notes
2D6 System-board and chassis assembly (I2C secondary)
2D7 System-board and chassis assembly (VPD module)
2E8 System-board and chassis assembly (cache controller)
308 System-board and chassis assembly (I/O bridge problem)
650 Unknown hard disk drive.
Note: This FFC indicates that the hard disk drive was not configured properly.
711 Unknown adapter
722 Unknown storage device
7C0 System-board and chassis assembly (microprocessor or system interface)
812 System-board and chassis assembly (common standard adapter logic problem)
815 System-board and chassis assembly (floating-point processor problem)
820 System-board and chassis assembly (interprocessor-related testing problem)
B88 System-board and chassis assembly (SAS controller)
D01 System-board and chassis assembly (cache problem)
E19 System-board and chassis assembly (power supply sensor failed)
25A0 System-board and chassis assembly
2627 IBM Flex System 2 port QDR InfiniBand adapter
2629 IBM Flex System 2 port QDR InfiniBand adapter (configuration problem)
2631 System-board and chassis assembly
268B 300 GB SAS small-form-factor disk drive
26B4 200 GB solid-state drive
26BD Cover (SAS to SATA bridge problem)
26D2 600 GB SAS small-form-factor disk drive
26D7 900 GB SAS small-form-factor disk drive
2710 System-board and chassis assembly (integrated USB controller)
2750 IBM Flex System 2-port 16 Gb Fibre Channel adapter
2755 IBM Flex System 4-port 16 Gb Fibre Channel adapter
2770 IBM Flex System 2-port 10 Gb RoCE adapter
2D14 System-board and chassis assembly (integrated SAS adapter)
2E16 IBM Flex System 2-port 8 Gb fibre channel adapter
2E28 IBM Flex System 8-port 10 Gb converged adapter
2E37 IBM Flex System 4-port 10 Gb Ethernet adapter
2E3D IBM Flex System 4-port 1 Gb Ethernet adapter
2E52 IBM Flex System 8-port 10 Gb converged adapter
Chapter 8. Troubleshooting 447