v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item Symptom Action
FSPSP42 An error
communicating
between two system
processors was
detected.
Contact your next level of support.
FSPSP45 The system has
detected an error
within the FSI path.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
FSPSP46 Some corrupt areas
of flash or RAM
have been detected
on the service
processor.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
FSPSP47 The system has
detected an error
within the PSI link.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
FSPSP48 A diagnostics
function detects an
external processor
interface problem.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.
FSPSP49 A diagnostic function
detects an internal
processor interface
problem.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.
FSPSP50 A diagnostic function
detects a connection
problem between a
processor chip and a
GX chip.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.
Chapter 8. Troubleshooting 479