Chapter 3. Systems management 83
IBM Flex System Chassis Management Module (CMM)
CMM is the default integrated platform for managing a single IBM Flex System Enterprise
Chassis. It occupies one of the two chassis management bays on the rear of the chassis.
A second module can be installed for redundancy.
More information regarding IBM Flex System Chassis Management Module can be found at
3.2.1, “Overview of IBM Flex System Chassis Management Module” on page 88.
I/O modules (switch modules)
I/O modules contain the internal management interfaces and Inter-Integrated Circuit (I2C) for
management. They can be managed by the IBM Flex System Manager, IBM Flex System
Chassis Management Module, command line interface (CLI), web interface, IBM System
Network Element Manager (SNEM), or any third-party SNMP-based management tool.
Compute node management processors
There are two types of compute nodes in an IBM Flex System:
򐂰 For IBM x86 (intel-based) compute nodes, the management interface is IMMv2, which is a
powerful management interface providing control at node-level.
򐂰 For POWER compute node, Flexible Service Processor(FSP) provides a serial-over-LAN
(SOL) interface for performing common management tasks on the node.
Table 3-1 gives an overview of system management capabilities of these hardware
management devices.
Table 3-1 System management
IBM Flex System Manager IBM Flex System Chassis
Management Module
IMMv2 / Flexible
Service Processor
Network Switch
򐂰 Remote access by browser
򐂰 Multi-Chassis Rack
Management
򐂰 Configuration and Updates
򐂰 Network Configuration
Manger
򐂰 Service & Support Manager
򐂰 Virtualization Management
(VM Control)
򐂰 Active Energy Manager
򐂰 Local Console for Chassis
Management
򐂰 Remote control for Compute
node(s)
򐂰 Aggregation point for
chassis
򐂰 Integrated Remote Chassis
Management
򐂰 Power and Thermal
Management
򐂰 Internal Chassis Network
with Management packet
forwarding
򐂰 Web, CLI, SNMP, CIM-XML
򐂰 CMM redundancy (optional
additional CMM)
򐂰 RAS, FFDC, Service
&Support, Chassis Event
Logs
򐂰 Remote Presence
(CLI/video/USB)
򐂰 Power and Thermal
Management.
򐂰 Inventory, Fault
detection
򐂰 Update
Management
򐂰 Configuration
Management
򐂰 RAS (reliability,
availability,
serviceability),
FFDC (First-failure
data capture), Logs
򐂰 Power, Thermal
sensing
򐂰 Update
Management
򐂰 Inventory, Fault
detection
򐂰 Configuration
Management
򐂰 RAS, FFDC
(First-failure data
capture), Logs
򐂰 SNMP, CLI, Web,
other proprietary
protocols

Table of Contents

Other manuals for IBM Flex System V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Flex System V7000 and is the answer not in the manual?

IBM Flex System V7000 Specifications

General IconGeneral
Form Factor2U
ModelIBM Flex System V7000
CategoryStorage
Power SupplyDual redundant power supplies
Storage ControllerDual active-active controllers
RAID LevelsRAID 0, 1, 5, 6, 10
Maximum Drives240
Expansion EnclosuresUp to 9
Drive Types SupportedSSD, HDD
Host Interface Ports8 Gbps FC
ScalabilityScalable with expansion enclosures
Operating Temperature5°C to 40°C
Management InterfaceWeb-based GUI, CLI, SMI-S