Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 840E SPCN default configuration loaded 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 87. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1011 840F I/O type not recognized 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 87. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1011 8413 Invalid processor 1 VPD Processor card
Location: U1.1-P1-C1
1011 8414 Invalid processor 2 VPD Processor card
Location: U1.1-P1-C2
1011 8423 No processor 1 VPD Processor card
Location: U1.1-P1-C1
1011 8424 No processor 2 VPD Processor card
Location: U1.1-P1-C2
1011 8430 V/S COMM cable not connected properly Check cabling
1011 8431 Frame ID error 1. Check cabling
2. From the main service processor menu,
select the System Information Menu,
then select the Power Control Network
Utilities Menu. Use option three to set
the I/O type to 87. Reboot the system.
3. Primary I/O drawer backplane
Location: U0.1-P1
1011 8441 Internal SPCN error in a drawer
1. Check the internal SPCN cables in the
CEC drawer Location: U1.1
2. Check the internal SPCN cables in the
I/O drawer Location: U0.x
1011 8450 The CEC processor(s) is (are) incompatible
with the CEC regulator
If a CEC processor or CEC regulator was
recently changed or if new firmware was
recently loaded, check the part numbers or
CCIN of the CEC processors and CEC
regulator. CEC regulator
Location: U1.1-P1-V1
Processor card
Locations: U1.1-P1-C1
U1.1-P1-C2
1011 8A00 A different I/O drawer is connected to the
CEC
Informational only
1011 9012 Invalid address 1. Check SPCN cabling
2. Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 173