Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4066 0217 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
4066 0218 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
4066 021D Scan interface basic assurance tests
detected memory DIMM group fault
Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
4066 021E Scan interface basic assurance tests
detected memory DIMM group pair A fault
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
4066 021F Scan interface basic assurance tests
detected memory DIMM group fault
Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
4066 0221 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
4066 0222 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
4066 0223 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
4066 0224 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
4066 0225 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
4066 0226 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
4066 0227 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 29, riser 1
Location: U1.1-P1-M1.29
4066 0228 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 30, riser 1
Location: U1.1-P1-M1.30
4066 022D Scan interface basic assurance tests
detected memory DIMM group fault
Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
4066 022E Scan interface basic assurance tests
detected memory DIMM group pair A fault
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
4066 022F Scan interface basic assurance tests
detected memory DIMM group fault
Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
4066 0231 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
4066 0232 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
4066 0233 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
4066 0234 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
4066 0235 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
4066 0236 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
4066 0237 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
Chapter 5. Error Code to FRU Index 211

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals