Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4067 0206 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
4067 0207 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
4067 0208 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
4067 020D 6xx bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
4067 020E 6xx bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4
4067 020F 6xx bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
4067 0211 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
4067 0212 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
4067 0213 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
4067 0214 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
4067 0215 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
4067 0216 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 20, riser 1
Location: U1.1-P1-M1.20
4067 0217 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
4067 0218 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
4067 021D 6xx bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
4067 021E 6xx bus processor runtime diagnostics
detected memory DIMM group pair A fault
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
4067 021F 6xx bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
4067 0221 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
4067 0222 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
4067 0223 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
4067 0224 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
4067 0225 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
4067 0226 6xx bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
Chapter 5. Error Code to FRU Index 217