Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4067 0601 6xx bus processor runtime diagnostics
detected clock card fault
CEC clock card
Location: U1.1-P1.1.1
4067 3101 6xx bus processor runtime diagnostics
detected RIO port 0 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3102 6xx bus processor runtime diagnostics
detected RIO port 1 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3103 6xx bus processor runtime diagnostics
detected RIO port 2 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3104 6xx bus processor runtime diagnostics
detected RIO port 3 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3121 6xx bus processor runtime diagnostics
detected RIO cable on port 0 fault
1. RIO cable on port 0
Location: U1.1-P1.1/Q1
2. CEC RIO bus adapter
Location: U1.1-P1.1
4067 3122 6xx bus processor runtime diagnostics
detected RIO cable on port 1 fault
1. RIO cable on port 1
Location: U1.1-P1.1/Q2
2. CEC RIO bus adapter
Location: U1.1-P1.1
4067 3123 6xx bus processor runtime diagnostics
detected RIO cable on port 2 fault
1. RIO cable on port 2
Location: U1.1-P1.1/Q3
2. CEC RIO bus adapter
Location: U1.1-P1.1
4067 3124 6xx bus processor runtime diagnostics
detected RIO cable on port 3 fault
1. RIO cable on port 3
Location: U1.1-P1.1/Q4
2. CEC RIO bus adapter
Location: U1.1-P1.1
4067 3140 6xx bus processor runtime diagnostics
detected RIO hub 0 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3141 6xx bus processor runtime diagnostics
detected RIO hub 1 fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 31FF 6xx bus processor runtime diagnostics
detected RIO port fault
CEC RIO bus adapter
Location: U1.1-P1.1
4067 3200 6xx bus processor runtime diagnostics
detected primary I/O drawer fault
Go to “MAP 1540: Minimum Configuration”
on page 110.
4067 3201 6xx bus processor runtime diagnostics
detected primary I/O drawer backplane fault
Primary I/O drawer backplane
Location: U0.1-P1
4067 3280 6xx bus processor runtime diagnostics
detected primary RIO adapter fault
Primary RIO adapter
Location: U0.1-P1.1
4067 3281 6xx bus processor runtime diagnostics
detected primary RIO port 0 fault
1. Check RIO cable
Location: U0.1-P1.1/Q1
2. RIO bus adapter
Location: U0.1-P1.1
4067 3282 6xx bus processor runtime diagnostics
detected primary RIO port 1 fault
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. RIO bus adapter
Location: U0.1-P1.1
4067 3283 6xx bus processor runtime diagnostics
detected primary RIO ports fault
RIO bus adapter
Location: U0.1-P1.1
Chapter 5. Error Code to FRU Index 221