Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4067 3284 6xx bus processor runtime diagnostics
detected PCI controller PHB0
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
4067 3285 6xx bus processor runtime diagnostics
detected PCI controller PHB1
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
4067 3286 6xx bus processor runtime diagnostics
detected PCI controller PHB2
1. RIO bus adapter
Location: U0.1-P1.1
2. Primary I/O drawer backplane
Location: U0.1-P1
4068 0001 Other bus processor runtime diagnostics
detected CEC backplane failure
CEC backplane
Location: U1.1-P1
4068 0003 Other bus processor runtime diagnostics
detected processor fault
All processors
Location: U1.1-P1-C1
4068 0009 Other bus processor runtime diagnostics
detected memory fault
All memory
Location: U1.1-P1-M1 x2
4068 00A0 Other bus processor runtime diagnostics
detected CSP service processor firmware
fault
Update system firmware
Location: U0.1-P1/Y1
4068 00A1 Other bus processor runtime diagnostics
detected AIX or system firmware fault
1. Check for AIX updates
2. Check for system firmware updates
Location: U0.1-P1/Y1
4068 00A2 Other bus processor runtime diagnostics
detected service processor firmware
(processor runtime diagnostics) fault
Check for system firmware updates
Location: U0.1-P1/Y1
4068 00A3 Other bus processor runtime diagnostics
detected memory plugging fault
All pluggable memory
4068 00A4 Other bus processor runtime diagnostics
detected application caused fault
Application software
4068 00A5 Other bus processor runtime diagnostics
detected invalid system configuration
Verify system components are supported and
properly installed.
4068 00A6 Other bus processor runtime diagnostics
detected no usable memory
1. Ensure that CEC memory is properly
installed.
2. If more than one DIMM is called out, go
to the service processor Memory
Configuration/Deconfiguration Menu to
verify memory DIMMs state. See
Memory Configuration/Deconfiguration
Menu on page 374 for more information.
4068 00A7 Other bus processor runtime diagnostics
detected hardware problem
Go to minimum configuration and also run
CEC minimum configuration
4068 00B0 Other bus processor runtime diagnostics
detected bus controller lock-unlock failure
RIO bus adapter
Location: U0.1-P1.1
4068 00B1 Other bus processor runtime diagnostics
detected bus controller failure
RIO bus adapter
Location: U0.1-P1.1