Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4068 00B3 Other bus processor runtime diagnostics
detected clock fault
1. Clock card
Location: U1.1-P1.1.1
2. CEC RIO bus adapter
Location: U1.1-P1.1
4068 00B7 Other bus processor runtime diagnostics
detected insufficient hardware resources to
continue IPL
This error code appears after the initial
testing by the service processor firmware on
the CEC was completed correctly, but a
problem occurred when the firmware tried to
communicate outside the CEC. Suspect a
problem with the RIO interface, either cables
or adapters.
4068 0200 Other bus processor runtime diagnostics
detected memory riser card fault
Memory riser card 1
Location: U1.1-P1-M1
4068 0201 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 1, riser 1
Location: U1.1-P1-M1.1
4068 0202 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 2, riser 1
Location: U1.1-P1-M1.2
4068 0203 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 9, riser 1
Location: U1.1-P1-M1.9
4068 0204 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 10, riser 1
Location: U1.1-P1-M1.10
4068 0205 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 17, riser 1
Location: U1.1-P1-M1.17
4068 0206 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 18, riser 1
Location: U1.1-P1-M1.18
4068 0207 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 25, riser 1
Location: U1.1-P1-M1.25
4068 0208 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 26, riser 1
Location: U1.1-P1-M1.26
4068 020D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal A, riser 1
Location: U1.1-P1-M1.1 x8
4068 020E Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad A odd, riser 1
Locations: U1.1-P1-M1.1 x4
4068 020F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad A even, riser 1
Locations: U1.1-P1-M1.2 x4
4068 0211 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 3, riser 1
Location: U1.1-P1-M1.3
4068 0212 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 4, riser 1
Location: U1.1-P1-M1.4
4068 0213 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 11, riser 1
Location: U1.1-P1-M1.11
4068 0214 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 12, riser 1
Location: U1.1-P1-M1.12
4068 0215 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 19, riser 1
Location: U1.1-P1-M1.19
4068 0216 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 20, riser 1
Location: U1.1-P1-M1.20
Chapter 5. Error Code to FRU Index 223