Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4068 0217 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 27, riser 1
Location: U1.1-P1-M1.27
4068 0218 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 28, riser 1
Location: U1.1-P1-M1.28
4068 021D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal B, riser 1
Location: U1.1-P1-M1.3 x8
4068 021E Other bus processor runtime diagnostics
detected memory DIMM group pair A fault
Memory quad B odd, riser 1
Location: U1.1-P1-M1.3 x4
4068 021F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad B even, riser 1
Location: U1.1-P1-M1.4 x4
4068 0221 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 5, riser 1
Location: U1.1-P1-M1.5
4068 0222 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 6, riser 1
Location: U1.1-P1-M1.6
4068 0223 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 13, riser 1
Location: U1.1-P1-M1.13
4068 0224 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 14, riser 1
Location: U1.1-P1-M1.14
4068 0225 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 21, riser 1
Location: U1.1-P1-M1.21
4068 0226 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 22, riser 1
Location: U1.1-P1-M1.22
4068 0227 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 29, riser 1
Location: U1.1-P1-M1.29
4068 0228 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 30, riser 1
Location: U1.1-P1-M1.30
4068 022D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal C, riser 1
Locations: U1.1-P1-M1.5 x8
4068 022E Other bus processor runtime diagnostics
detected memory DIMM group pair A fault
Memory quad C odd, riser 1
Locations: U1.1-P1-M1.5 x4
4068 022F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad C even, riser 1
Locations: U1.1-P1-M1.6 x4
4068 0231 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 7, riser 1
Location: U1.1-P1-M1.7
4068 0232 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 8, riser 1
Location: U1.1-P1-M1.8
4068 0233 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 15, riser 1
Location: U1.1-P1-M1.15
4068 0234 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 16, riser 1
Location: U1.1-P1-M1.16
4068 0235 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 23, riser 1
Location: U1.1-P1-M1.23
4068 0236 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 24, riser 1
Location: U1.1-P1-M1.24
4068 0237 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 31, riser 1
Location: U1.1-P1-M1.31
224 Service Guide