Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4068 0238 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 32, riser 1
Location: U1.1-P1-M1.32
4068 023D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal D, riser 1
Location: U1.1-P1-M1.7 x8
4068 023E Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad D odd, riser 1
Location: U1.1-P1-M1.7 x4
4068 023F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad D even, riser 1
Location: U1.1-P1-M1.8 x4
4068 02FF Other bus processor runtime diagnostics
detected memory on riser fault
All memory on riser 1
Location: U1.1-P1-M1.1 x32
Memory failure on riser card 1 that cannot be
automatically isolated. go to “MAP 1540:
Minimum Configuration” on page 110 and run
CEC drawer minimum configuration for
further isolation.
4068 0300 Other bus processor runtime diagnostics
detected processor card fault
Processor card
Location: U1.1-P1-C1
4068 0400 Other bus processor runtime diagnostics
detected processor card fault
Processor card
Location: U1.1-P1-C2
4068 0500 Other bus processor runtime diagnostics
detected memory riser card fault
Memory riser card 2
Location: U1.1-P1-M1
4068 0501 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 1, riser 2
Location: U1.1-P1-M2.1
4068 0502 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 2, riser 2
Location: U1.1-P1-M2.2
4068 0503 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 9, riser 2
Location: U1.1-P1-M2.9
4068 0504 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 10, riser 2
Location: U1.1-P1-M2.10
4068 0505 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 17, riser 2
Location: U1.1-P1-M2.17
4068 0506 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 18, riser 2
Location: U1.1-P1-M2.18
4068 0507 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 25, riser 2
Location: U1.1-P1-M2.25
4068 0508 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 26, riser 2
Location: U1.1-P1-M2.26
4068 050D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal A, riser 2
Location: U1.1-P1-M2.1 x8
4068 050E Other bus processor runtime diagnostics
detected memory DIMM group pair A fault
Memory quad A odd, riser 2
Location: U1.1-P1-M2.1 x4
4068 050F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad A even, riser 2
Location: U1.1-P1-M2.2 x4
4068 0511 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 3, riser 2
Location: U1.1-P1-M2.3
4068 0512 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 4, riser 2
Location: U1.1-P1-M2.4
Chapter 5. Error Code to FRU Index 225