Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4068 0513 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 11, riser 2
Location: U1.1-P1-M2.11
4068 0514 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 12, riser 2
Location: U1.1-P1-M2.12
4068 0515 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 19, riser 2
Location: U1.1-P1-M2.19
4068 0516 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 20, riser 2
Location: U1.1-P1-M2.20
4068 0517 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 27, riser 2
Location: U1.1-P1-M2.27
4068 0518 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 28, riser 2
Location: U1.1-P1-M2.28
4068 051D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal B, riser 2
Location: U1.1-P1-M2.3 x8
4068 051E Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad B odd, riser 2
Location: U1.1-P1-M2.3 x4
4068 051F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad B even, riser 2
Location: U1.1-P1-M2.4 x4
4068 0521 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 5, riser 2
Location: U1.1-P1-M2.5
4068 0522 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 6, riser 2
Location: U1.1-P1-M2.6
4068 0523 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 13, riser 2
Location: U1.1-P1-M2.13
4068 0524 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 14, riser 2
Location: U1.1-P1-M2.14
4068 0525 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 21, riser 2
Location: U1.1-P1-M2.21
4068 0526 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 22, riser 2
Location: U1.1-P1-M2.22
4068 0527 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 29, riser 2
Location: U1.1-P1-M2.29
4068 0528 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 30, riser 2
Location: U1.1-P1-M2.30
4068 052D Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory octal C, riser 2
Location: U1.1-P1-M2.5 x8
4068 052E Other bus processor runtime diagnostics
detected memory DIMM group pair A fault
Memory quad C odd, riser 2
Location: U1.1-P1-M2.5 x4
4068 052F Other bus processor runtime diagnostics
detected memory DIMM group fault
Memory quad C even, riser 2
Location: U1.1-P1-M2.6 x4
4068 0531 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 7, riser 2
Location: U1.1-P1-M2.7
4068 0532 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 8, riser 2
Location: U1.1-P1-M2.8
4068 0533 Other bus processor runtime diagnostics
detected memory DIMM fault
Memory DIMM 15, riser 2
Location: U1.1-P1-M2.15
226 Service Guide