EasyManuals Logo

IBM Storwize V7000 Maintenance Guide

IBM Storwize V7000
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
Table 26. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
010025 W A disk I/O medium error has occurred. 1320
010026 W A suitable MDisk or drive for use as a quorum disk was
not found.
1330
010027 W The quorum disk is not available. 1335
010028 W A controller configuration is not supported. 1625
010029 E A login transport fault has occurred. 1360
010030 E A managed disk error recovery procedure (ERP) has
occurred. The node or controller reported the following:
v Sense
v Key
v Code
v Qualifier
1370
010031 E One or more MDisks on a controller are degraded. 1623
010032 W The controller configuration limits failover. 1625
010033 E The controller configuration uses the RDAC mode; this is
not supported.
1624
010034 E Persistent unsupported controller configuration. 1695
010040 E The controller system device is only connected to the
node through a single initiator port.
1627
010041 E The controller system device is only connected to the
node through a single target port.
1627
010042 E The controller system device is only connected to the
cluster (system) nodes through a single target port.
1627
010043 E The controller system device is only connected to the
cluster (system) nodes through half of the expected
target ports.
1627
010044 E The controller system device has disconnected all target
ports to the cluster (system) nodes.
1627
010050 W A solid-state drive (SSD) failed. A rebuild is required. 1201
010051 E A solid-state drive (SSD) is missing. 1202
010052 E A solid-state drive (SSD) is offline as a result of a drive
hardware error.
1205
010053 E A solid-state drive (SSD) is reporting a predictive failure
analysis (PFA).
1215
010054 E A solid-state drive (SSD) is reporting too many errors. 1215
010055 W An unrecognized SAS device. 1665
010056 E SAS error counts exceeded the warning thresholds. 1216
010057 E SAS errors exceeded critical thresholds. 1216
010058 E The drive initialization failed because of an unknown
block size or a block size that is not valid; an unknown
capacity or a capacity that is not valid; or was not able to
set the required mode pages.
1661
010059 E A solid-state drive (SSD) is offline due to excessive
errors.
1311
122 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize